Description:

AirSeal iFS

Intelligent insufflation

AirSealAirSeal iFS

The world’s first 3‑in‑1 insufflator.

AirSeal is unrivaled in its ability to maintain a stable pneumoperitoneum, constant evacuation of surgical smoke, and allows the surgeon to operate at low intra-abdominal pressure.

The AirSeal iFS insufflator.

Robotic solution

Pressure control is a safeguard, not a setting

Designed for stability. Proven to benefit patients.

In minimally invasive robotic surgery, pressure control isn’t just a setting. It’s a safeguard for your patients. AirSeal® delivers unmatched stability in pneumoperitoneum, allowing you to operate confidently at lower pressures without sacrificing visibility.

  • Stable pneumoperitoneum, regardless of leakage or use of suction.
  • Constant smoke evacuation with 0.01 µ ULPA filtration.
  • Valveless access through the AirSeal trocar.
The AirSeal trocar with its filter tube set.

Low pressure laparoscopy

Lower pressure, same view

Low-pressure laparoscopic surgery has previously been difficult due to limitations associated with conventional insufflators.

AirSeal compared with a conventional insufflator: peak airway pressure, end tidal CO2, arterial pressure and insufflation pressure.

The AirSeal System’s unique ability to maintain a stable pneumoperitoneum and constantly eliminate surgical smoke allows surgeons to operate at lower pressures without compromising exposure and visualization. By maintaining a stable pneumoperitoneum, constant elimination of surgical smoke and a valveless access through the AirSeal trocar, the AirSeal System has been shown to reduce operating time, increasing the efficiency associated with surgery.

See the difference

Low pressure surgery

AirSeal on the left, conventional insufflation on the right.

Three options

One system, three ways to run it

The filter set decides which mode you are in. The generator is the same.

01 3-lumen filter

AirSeal mode

By using AirSeal with the 3-lumen filter, you get the following benefits:

  • Optimised CO2 flow to maintain a stable pneumoperitoneum — regardless of leakage or use of suction.
  • Smoke evacuation and filtration with 0.01 µ ULPA filter.
  • Allows you to operate at lower intra-abdominal pressure (6–8 mmHg), which has many per- and post-operative benefits for patients.
02 Bifurcated, double-lumen

Smoke evacuation mode

Use AirSeal with a bifurcated, double-lumen filter set. This allows for high-flow insufflation and good smoke evacuation with filtration with 0.01 µ ULPA filter.

03 Single-lumen hose

Standard insufflation mode

Use AirSeal with a single lumen hose set for high-flow insufflation.

Documentation

Download material

Ferdinand Medical

See AirSeal in your own operating room

Contact us